fault F1125

How to resolve fault F1125 with the name fltVzRsInTermGraphAttResolveFail

Cisco System Model: Fault fltVzRsInTermGraphAttResolveFail

Cisco System Model: Class ifc:policymgr:fltVzRsInTermGraphAttResolveFail

This pages provides an overview over ACI Fault: F1125

Explanation: The object refers to an object that was not found.
Recommended Action: Make sure that referenced object exists and the name is spelled correctly in the relation object.

Raised on MO: vz:RsInTermGraphAtt
Fault Name: fltVzRsInTermGraphAttResolveFail

Unqualified API Name: ResolveFail

Code: F1125
Applied Mo DN Format

  • topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/oobbrc-[name]/subj-[name]/intmnl/rsInTermGraphAtt
  • uni/tn-[name]/oobbrc-[name]/subj-[name]/intmnl/rsInTermGraphAtt
  • topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/brc-[name]/subj-[name]/intmnl/rsInTermGraphAtt
  • uni/tn-[name]/brc-[name]/subj-[name]/intmnl/rsInTermGraphAtt
  • topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/subj-[name]/intmnl/rsInTermGraphAtt
  • uni/tn-[name]/subj-[name]/intmnl/rsInTermGraphAtt

Type: config
Cause: resolution-failed
Severity: warning
Weight: 100
Tags:
Message: None
Help: None
Triggered By: state equals missing-target

Related content