Cisco System Model: Fault fltMgmtConfigAddrDuplicateMgmtAddr
Cisco System Model: Class ifc:policymgr:fltMgmtConfigAddrDuplicateMgmtAddr
This pages provides an overview over ACI Fault: F1726
Explanation: This fault occurs when the same IP address is configured on multiple nodes.
Recommended Action: If you see this fault, take the following actions: Identify the nodes that are using the same IP address. Fix address pools, or the static IP that is assigned to the conflicting nodes. If above actions did not resolve the issue, create a tech-support file and contact Cisco TAC.
Raised on MO: mgmt:ConfigAddr
Fault Name: fltMgmtConfigAddrDuplicateMgmtAddr
Unqualified API Name: duplicateMgmtAddr
Code: F1726
Applied Mo DN Format
- topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/instp-[epgPKey]/addrcont/caddr-[addr]
- uni/epp/instp-[epgPKey]/addrcont/caddr-[addr]
- topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/inb-[epgPKey]/addrcont/caddr-[addr]
- uni/epp/inb-[epgPKey]/addrcont/caddr-[addr]
- topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/oob-[epgPKey]/addrcont/caddr-[addr]
- uni/epp/oob-[epgPKey]/addrcont/caddr-[addr]
- topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/addrcont/caddr-[addr]
- uni/epp/addrcont/caddr-[addr]
Type: config
Cause: configuration-failed
Severity: minor
Weight: 100
Tags:
Message: None
Help: None
Triggered By: numProvs not equals 1