Cisco System Model: Fault fltL2BDNoOptArpFwdWithUnkMacFlood
Cisco System Model: Class ifc:eventmgr:fltL2BDNoOptArpFwdWithUnkMacFlood
This pages provides an overview over ACI Fault: F1364
Explanation: This fault occurs when the arp flood knob is not set in bridge only mode
Recommended Action: To recover from this fault, try the following actions Set the arp flood knob for this BD If the above actions did not resolve the issue, generate the show tech-support file and contact Cisco TAC.
Raised on MO: l2:BD
Fault Name: fltL2BDNoOptArpFwdWithUnkMacFlood
Unqualified API Name: noOptArpFwdWithUnkMacFlood
Code: F1364
Applied Mo DN Format
- topology/pod-[id]/node-[id]/sys/ctxsubstitute-[encap]/bd-[fabEncap]
- sys/ctxsubstitute-[encap]/bd-[fabEncap]
- topology/pod-[id]/node-[id]/sys/inst-[name]/bd-[fabEncap]
- sys/inst-[name]/bd-[fabEncap]
- topology/pod-[id]/node-[id]/sys/ctx-[encap]/bd-[fabEncap]
- sys/ctx-[encap]/bd-[fabEncap]
Type: operational
Cause: bd-provisioning-failed
Severity: warning
Weight: 100
Tags:
Message: None
Help: None
Triggered By: not fwdCtrl contains arp-flood and unkMacUcastAct equals flood