fault F1318

How to resolve fault F1318 with the name fltEqptPsgPZeroPwr

Cisco System Model: Fault fltEqptPsgPZeroPwr

Cisco System Model: Class ifc:eventmgr:fltEqptPsgPZeroPwr

This pages provides an overview over ACI Fault: F1318

Explanation: This fault occurs when PSU are not detected correctly
Recommended Action: To recover from this fault, try the following actions Properly seat the power supplies Remove mismatched power supplies If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC

Raised on MO: eqpt:PsgP
Fault Name: fltEqptPsgPZeroPwr

Unqualified API Name: zeroPwr

Code: F1318
Applied Mo DN Format

  • topology/pod-[id]/node-[id]/sys/ops/psgp
  • sys/ops/psgp

Type: environmental
Cause: equipment-psu-missing
Severity: major
Weight: 100
Tags:
Message: None
Help: None
Triggered By: tc equals 0u