Cisco System Model: Fault fltArpStAdjEpOperStDown
Cisco System Model: Class ifc:eventmgr:fltArpStAdjEpOperStDown
This pages provides an overview over ACI Fault: F1207
Explanation: This fault occurs when the operational state of the arp adjacency is down
Recommended Action: To recover from this fault, try the following actions Look at any configuration issues Verify the configuration is correct/complete Ensure the port is up on which ARP is configured
Raised on MO: arp:StAdjEp
Fault Name: fltArpStAdjEpOperStDown
Unqualified API Name: operStDown
Code: F1207
Applied Mo DN Format
- topology/pod-[id]/node-[id]/sys/arp/inst/dom-[name]/if-[id]/sadj-[ip]
- sys/arp/inst/dom-[name]/if-[id]/sadj-[ip]
Type: operational
Cause: protocol-arp-adjacency-down
Severity: warning
Weight: 100
Tags:
Message: None
Help: None
Triggered By: operSt equals down